Transmitters - xMeters with Display - Apuissance3-EN

Go to content

Main menu:

Transmitters - xMeters with Display

ATEX products > Transmitters - xMeters with Display

XT42SI

4-20 mA Transmitter for hazardous areas
• Usable in hazardous areas, Gas or Dust : G or D according ATEX/94/9/CE
• 4-20 mA, 2-wire transmitter
• Inputs : RTD100 to RTD1000, Ni100 to 1000, resistor 0 to 100KΩ
• Potentiometer input
• Adjustable on large ranges
• Miniaturised and low cost due to SMT

XT4.SI avec SONDE

RTD100 or thermocouple Industrial Temperature Sensors for Hazardous Area
• material stainless-steel 316L
• sensitive element standard RTD100 Class A 100 Ω at 0 ° C according to NF EN 60751/A2
• Industrial probe with head connection
• temperature sensor eyelet
• thermowell drilled through or mechanically welded
• simple 4-20 mA, 2-wire transmitter or Hart ® compatible

XT42SI-NIV

4-20mA Transmetter for hazardous areas
• Usable in hazardous areas, Gas or Dust : G or D according ATEX/94/9/CE
• 4-20 mA, 2-wires transmitter
• Potentiometer input 0 to 1KΩ or 0 to 100KΩ
• Adjustable on large ranges
• Miniaturised and low cost due to SMT

XT42SI-30S

4-20 mA Transmitter for hazardous areas
• Usable in hazardous areas, Gas or Dust : G or D according ATEX/94/9/CE
• 4-20 mA, 2-wire transmitter
• Inputs : RTD100 to RTD1000, Ni100 to 1000, resistor 0 to 4000 Ω
• J, K, T, E, S, W5 thermocouple input
• Potentiometer input
• Special linearization for level application
• Hart ® compatible
• Adjustable on large ranges
• Miniaturised and low cost due to SMT
• DIN rail housing 1 or 2 channels.

XT42SI-30D

4-20 mA Transmitter for hazardous areas
• Usable in hazardous areas, Gas or Dust : G or D according ATEX/94/9/CE
• 4-20 mA, 2-wire transmitter
• Inputs : RTD100 to RTD1000, Ni100 to 1000, resistor 0 to 4000 Ω
• J, K, T, E, S, W5 thermocouple input
• Potentiometer input
• Special linearization for level application
• Hart ® compatible
• Adjustable on large ranges
• Miniaturised and low cost due to SMT
• DIN rail housing 1 or 2 channels.

XT43SIH

4-20 mA Transmitter for hazardous areas
• Usable in hazardous areas, Gas or Dust : G or D according ATEX/94/9/CE
• 4-20 mA, 2-wire transmitter
• Inputs : RTD100 to RTD1000, Ni100 to 1000, resistor 0 to 4,000 Ω
• Potentiometer input
• Special linearization for level application
• Hart ® compatible
• Adjustable on large ranges
• Miniaturised and low cost due to SMT

INDEX2-HWT-T1

Loop-powered digital indicator with temperature input (RTD-Pt100 and so on) or potentiometer with 4-20mA output HART ®
• For use in ATEX hazardous areas G or D
• Temperature input RTD100 to RTD1000, Ni100 to 1000
• Potentiometer or resistor input
• Output 4-20 mA
• LCD 4 ½ digits display (+/- 20,000 counts)
• IP54 housing
• Programmable by keypads on front panel
• 2 alarm switches with hysteresis and delay
• Minimal, maximal values, modulo, signal filter

INDEX2-HWT-BCL

oop-powered digital indicator with temperature input (RTD-Pt100 and so on) or potentiometer with 4-20mA output HART ®
• For use in ATEX hazardous areas G or D
• Temperature input RTD100 to RTD1000, Ni100 to 1000
• Potentiometer or resistor input
• Output 4-20 mA
• LCD 4 ½ digits display (+/- 20,000 counts)
• IP65 housing
• Programmable by inner keypads
• 2 alarm switches with hysteresis and delay
• Minimal, maximal values, modulo, signal filter

INDEX2-HWT-POT

Loop-powered digital indicator with setpoint potentiometer and 4-20mA output HART ®
• For use in ATEX hazardous areas G or D
• Setpoint Potentiometer built
• Output 4-20 mA
• LCD 4 ½ digits display (+/- 20,000 counts)
• IP65 housing
• Programmable by inner keypads
• 2 alarm switches with hysteresis and delay
• Minimal, maximal values, modulo, signal filter

Back to content | Back to main menu